Rabbit Oxidized low-density lipoprotein ELISA Kit

Pe scurt

Rabbit Oxidized low-density lipoprotein ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea Oxidized low-density lipoprotein, cu reactivitate declarată pentru Rabbit. Măsoară în domeniul 3.125-200 ng/ml, are o sensibilitate de 1.875 ng/ml și folosește detecție Colorimetric Detection (OD450). Se livrează în mărimea 96T, la prețul de 4.625,23 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Rabbit Oxidized low-density lipoprotein ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of rabbit Oxidized low-density lipoprotein in serum, plasma, cell culture supernatant, cell or tissue lysate, and other liquid samples.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Applications
Sandwich ELISA
Reactivity
Rabbit
Sensitivity
1.875 ng/ml
Product range
3.125-200 ng/ml
Assay Time
4 hours
Principiul testului
Rabbit Oxidized low-density lipoprotein ELISA Kit (A335438) is a 4 hour sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of rabbit Oxidized low-density lipoprotein in serum, plasma, cell culture supernatant, cell or tissue lysate, and other biological fluids. A 96-well microtiter plate has been pre-coated with an antibody specific for Oxidized low-density lipoprotein. Standards and samples are added to the wells, where Oxidized low-density lipoprotein binds to the immobilized capture antibody. Following incubation, unbound components are removed by washing and a biotinylated detection antibody specific for Oxidized low-density lipoprotein is added to the wells. The detection antibody binds the captured Oxidized low-density lipoprotein to form an antibody-antigen-antibody sandwich complex. After further incubation and washing, HRP-Streptavidin conjugate is added to the wells. TMB substrate solution is then added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the yellow colour is directly proportional to the amount of Oxidized low-density lipoprotein captured in each well. The concentration of Oxidized low-density lipoprotein is calculated by reading the absorbance at 450 nm and comparing the values with the standard curve.

Documentație

Produse similare

Ai nevoie de ajutor?

Nu găsești produsul potrivit? Scrie-ne cerințele și îți răspundem cu o recomandare și un preț.