Rabbit VCAM1 ELISA Kit

Pe scurt

Rabbit VCAM1 ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea VCAM1, cu reactivitate declarată pentru Rabbit. Măsoară în domeniul 0.469-30 ng/ml, are o sensibilitate de 0.281 ng/ml și folosește detecție Colorimetric Detection (OD450). Se livrează în mărimea 96T, la prețul de 4.625,23 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Rabbit VCAM1 ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of rabbit VCAM1 in serum, plasma, cell culture supernatant, cell or tissue lysate, and other liquid samples.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Țintă
VCAM1
Applications
Sandwich ELISA
Reactivity
Rabbit
Sensitivity
0.281 ng/ml
Product range
0.469-30 ng/ml
Assay Time
4 hours
Principiul testului
Rabbit VCAM1 ELISA Kit (A335432) is a 4 hour sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of rabbit VCAM1 in serum, plasma, cell culture supernatant, cell or tissue lysate, and other biological fluids. A 96-well microtiter plate has been pre-coated with an antibody specific for VCAM1. Standards and samples are added to the wells, where VCAM1 binds to the immobilized capture antibody. Following incubation, unbound components are removed by washing and a biotinylated detection antibody specific for VCAM1 is added to the wells. The detection antibody binds the captured VCAM1 to form an antibody-antigen-antibody sandwich complex. After further incubation and washing, HRP-Streptavidin conjugate is added to the wells. TMB substrate solution is then added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the yellow colour is directly proportional to the amount of VCAM1 captured in each well. The concentration of VCAM1 is calculated by reading the absorbance at 450 nm and comparing the values with the standard curve.