Rabbit CXCL10 ELISA Kit

Pe scurt

Rabbit CXCL10 ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea CXCL10, cu reactivitate declarată pentru Rabbit. Măsoară în domeniul 7.813-500 pg/ml, are o sensibilitate de 4.688 pg/ml și folosește detecție Colorimetric Detection (OD450). Se livrează în mărimea 96T, la prețul de 4.625,23 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Rabbit CXCL10 ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of rabbit CXCL10 in serum, plasma, cell culture supernatant, cell or tissue lysate, and other liquid samples.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Țintă
CXCL10
Applications
Sandwich ELISA
Reactivity
Rabbit
Sensitivity
4.688 pg/ml
Product range
7.813-500 pg/ml
Assay Time
4 hours
Principiul testului
Rabbit CXCL10 ELISA Kit (A335440) is a 4 hour sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of rabbit CXCL10 in serum, plasma, cell culture supernatant, cell or tissue lysate, and other biological fluids. A 96-well microtiter plate has been pre-coated with an antibody specific for CXCL10. Standards and samples are added to the wells, where CXCL10 binds to the immobilized capture antibody. Following incubation, unbound components are removed by washing and a biotinylated detection antibody specific for CXCL10 is added to the wells. The detection antibody binds the captured CXCL10 to form an antibody-antigen-antibody sandwich complex. After further incubation and washing, HRP-Streptavidin conjugate is added to the wells. TMB substrate solution is then added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the yellow colour is directly proportional to the amount of CXCL10 captured in each well. The concentration of CXCL10 is calculated by reading the absorbance at 450 nm and comparing the values with the standard curve.