Pe scurt
Nitrofurantoin ELISA Kit este un kit ELISA de tip Competitive (quantitative) pentru măsurarea Nitrofurantoin. Măsoară în domeniul Detection Limit 0.06 ng/g or ppb, are o sensibilitate de 0.03 ng/g or ppb, folosește detecție Colorimetric și se poate folosi pe probe de tip Fish, shrimp, meat (chicken, beef, pork and hepar), eggs, honey. Se livrează în mărimea 96T, la prețul de 2.562,18 lei cu TVA.
Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.
Descriere
Nitrofurantoin ELISA Kit is a competitive Enzyme-Linked Immunosorbent Assay (cELISA) designed for the in vitro quantitative determination of Nitrofurantoin in fish, shrimp, meat (chicken, beef, pork and hepar), eggs, honey.
Citește mai multArată mai puțin
Specificații
- Brand
- Antibodies
- Mărime
- 96T
- Țintă
- Nitrofurantoin
- Applications
- Competitive ELISA
- Assay type
- Competitive (quantitative)
- Sensitivity
- 0.03 ng/g or ppb
- Detection type
- Colorimetric
- Product range
- Detection Limit 0.06 ng/g or ppb.
- Assay Time
- 4 hours
- Recovery
- 80-105%
- Principiul testului
- Nitrofurantoin ELISA Test Kit (A327231) employs the competitive enzyme immunoassay technique for the quantitative measurement of Nitrofurantoin in fish, shrimp, meat (chicken, beef, pork and hepar), eggs, honey. The 96-well microtiter plate has been pre-coated with Nitrofurantoin. During the incubation, Nitrofurantoin present in the samples or standards competes with the fixed amount of immobilized Nitrofurantoin for binding sites of the Anti-Nitrofurantoin Antibody, a HRP-Conjugated Secondary Antibody is added to the wells at the same time. The more Nitrofurantoin present in a sample or standard, the less Anti-Nitrofurantoin Antibody that binds to the plate. Following incubation, unbound HRP-Conjugated Secondary Antibody is removed by washing. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is inversely proportional to the amount of Nitrofurantoin present in each sample or standard. The concentration of Nitrofurantoin can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.