Mouse MCM7/PRL ELISA Kit

Pe scurt

Mouse MCM7/PRL ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea MCM7/PRL, cu reactivitate declarată pentru Mouse. Măsoară în domeniul 0.31-20 ng/ml, are o sensibilitate de 0.186 ng/mL, folosește detecție Colorimetric Detection (OD450) și se poate folosi pe probe de tip Serum, plasma and other biological fluids. Se livrează în mărimea 96T, la prețul de 3.826,63 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Mouse MCM7/PRL ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay designed for the in vitro quantitative determination of mouse MCM7/PRL in serum, plasma, and other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Țintă
MCM7/PRL
Applications
Sandwich ELISA
Reactivity
Mouse
Sensitivity
0.186 ng/mL
Product range
0.31-20 ng/ml
Assay Time
3h 30m
Principiul testului
Mouse MCM7/PRL ELISA Kit (A327048) employs the sandwich enzyme immunoassay technique for the quantitative measurement of mouse MCM7/PRL in serum, plasma, and other biological fluids. An antibody specific for MCM7/PRL has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the MCM7/PRL present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-MCM7/PRL Antibody, which binds the captured MCM7/PRL present in each well. Following incubation, unbound biotinylated detection antibody is removed by washing, and an HRP-Streptavidin conjugate is added to the wells and the microtiter plate is incubated. Following incubation and washing, substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of MCM7/PRL captured in each well. The concentration of MCM7/PRL can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.