Sari la conținut
Coșul meu

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Mouse Thromboxane B2 ELISA Kit

Pe scurt

Mouse Thromboxane B2 ELISA Kit este un kit ELISA de tip Competitive (quantitative) pentru măsurarea Thromboxane B2, cu reactivitate declarată pentru Mouse. Măsoară în domeniul 15.63 - 1000 pg/ml, are o sensibilitate de 9.38 pg/ml, folosește detecție Colorimetric Detection (OD450) și se poate folosi pe probe de tip Serum, plasma and other biological fluids. Se livrează în mărimea 96T, la prețul de 3.826,63 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Mouse Thromboxane B2 ELISA Kit is a competitive Enzyme-Linked Immunosorbent Assay designed for the in vitro quantitative determination of mouse Thromboxane B2 in serum, plasma, and other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Applications
Competitive ELISA
Reactivity
Mouse
Sensitivity
9.38 pg/ml
Product range
15.63 - 1000 pg/ml
Assay Time
2 hours
Principiul testului
Mouse Thromboxane B2 ELISA Kit (A327042) employs the competitive enzyme immunoassay technique for the quantitative measurement of mouse Thromboxane B2 in serum, plasma, and other biological fluids. The 96-well microtiter plate has been pre-coated with Thromboxane B2 antigen. During the incubation, Thromboxane B2 present in the samples or standards competes with the fixed amount of immobilized Thromboxane B2 for binding sites on the Biotinylated Anti-Thromboxane B2 Antibody. The more Thromboxane B2 present in a sample or standard, the less Biotinylated Anti-Thromboxane B2 Antibody that binds to the plate. Following incubation, unbound Biotinylated Anti-Thromboxane B2 Antibody is removed by washing, and an HRP-Streptavidin conjugate is added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is inversely proportional to the amount of Thromboxane B2 present in each sample or standard. The concentration of Thromboxane B2 can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.

Produse similare

Ai nevoie de ajutor?

Nu găsești produsul potrivit? Scrie-ne cerințele și îți răspundem cu o recomandare și un preț.

Solicită consultanță

Achiziții publice

Suntem înregistrați în SEAP și livrăm către instituții publice, cu documentație completă.

Cum cumperi prin SEAP →

Contact