Sari la conținut
Coșul meu

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

4-Hydroxynonenal ELISA Kit

Pe scurt

4-Hydroxynonenal ELISA Kit este un kit ELISA de tip Competitive (quantitative) pentru măsurarea 4-Hydroxynonenal, cu reactivitate declarată pentru Universal. Măsoară în domeniul 0.63 - 40 ng/ml, are o sensibilitate de 0.38 ng/ml, folosește detecție Colorimetric Detection (OD450) și se poate folosi pe probe de tip Serum, plasma and other biological fluids. Se livrează în mărimea 96T, la prețul de 3.227,68 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

4-Hydroxynonenal ELISA Kit is a competitive Enzyme-Linked Immunosorbent Assay designed for the in vitro quantitative determination of 4-Hydroxynonenal in serum, plasma, and other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Applications
Competitive ELISA
Reactivity
Universal
Sensitivity
0.38 ng/ml
Product range
0.63 - 40 ng/ml
Assay Time
2 hours
Principiul testului
4-Hydroxynonenal ELISA Kit (A326989) employs the competitive enzyme immunoassay technique for the quantitative measurement of 4-Hydroxynonenal in serum, plasma, and other biological fluids. The 96-well microtiter plate has been pre-coated with 4-Hydroxynonenal antigen. During the incubation, 4-Hydroxynonenal present in the samples or standards competes with the fixed amount of immobilized 4-Hydroxynonenal for binding sites on the Biotinylated Anti-4-Hydroxynonenal Antibody. The more 4-Hydroxynonenal present in a sample or standard, the less Biotinylated Anti-4-Hydroxynonenal Antibody that binds to the plate. Following incubation, unbound Biotinylated Anti-4-Hydroxynonenal Antibody is removed by washing, and an HRP-Streptavidin conjugate is added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is inversely proportional to the amount of 4-Hydroxynonenal present in each sample or standard. The concentration of 4-Hydroxynonenal can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.

Produse similare

Ai nevoie de ajutor?

Nu găsești produsul potrivit? Scrie-ne cerințele și îți răspundem cu o recomandare și un preț.

Solicită consultanță

Achiziții publice

Suntem înregistrați în SEAP și livrăm către instituții publice, cu documentație completă.

Cum cumperi prin SEAP →

Contact