Sari la conținut
Coșul meu

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Substance P ELISA Kit

Pe scurt

Substance P ELISA Kit este un kit ELISA de tip Competitive (quantitative) pentru măsurarea Substance P, cu reactivitate declarată pentru Universal. Măsoară în domeniul 78.13 - 5000 pg/ml, are o sensibilitate de 46.88 pg/ml, folosește detecție Colorimetric Detection (OD450) și se poate folosi pe probe de tip Serum, plasma and other biological fluids. Se livrează în mărimea 96T, la prețul de 3.227,68 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Substance P ELISA Kit is a competitive Enzyme-Linked Immunosorbent Assay designed for the in vitro quantitative determination of Substance P in serum, plasma, and other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Applications
Competitive ELISA
Reactivity
Universal
Sensitivity
46.88 pg/ml
Product range
78.13 - 5000 pg/ml
Assay Time
2 hours
Principiul testului
Substance P ELISA Kit (A326981) employs the competitive enzyme immunoassay technique for the quantitative measurement of Substance P in serum, plasma, and other biological fluids. The 96-well microtiter plate has been pre-coated with Substance P antigen. During the incubation, Substance P present in the samples or standards competes with the fixed amount of immobilized Substance P for binding sites on the Biotinylated Anti-Substance P Antibody. The more Substance P present in a sample or standard, the less Biotinylated Anti-Substance P Antibody that binds to the plate. Following incubation, unbound Biotinylated Anti-Substance P Antibody is removed by washing, and an HRP-Streptavidin conjugate is added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is inversely proportional to the amount of Substance P present in each sample or standard. The concentration of Substance P can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.

Produse similare

Ai nevoie de ajutor?

Nu găsești produsul potrivit? Scrie-ne cerințele și îți răspundem cu o recomandare și un preț.

Solicită consultanță

Achiziții publice

Suntem înregistrați în SEAP și livrăm către instituții publice, cu documentație completă.

Cum cumperi prin SEAP →

Contact