Universal Poly (ADP-Ribose) Polymer ELISA Kit

Pe scurt

Universal Poly (ADP-Ribose) Polymer ELISA Kit este un kit ELISA de tip Competitive (quantitative) pentru măsurarea Poly (ADP-Ribose) Polymer, cu reactivitate declarată pentru Universal. Măsoară în domeniul 0.156-10 pmol/ml, are o sensibilitate de 0.094 pmol/ml, folosește detecție Colorimetric Detection (OD450) și se poate folosi pe probe de tip Serum, plasma, tissue homogenates, and other biological fluids. Se livrează în mărimea 96T, la prețul de 4.591,95 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Universal Poly (ADP-Ribose) Polymer ELISA Kit is a competitive Enzyme-Linked Immunosorbent Assay (cELISA) designed for the in vitro quantitative determination of universal Poly (ADP-Ribose) Polymer in serum, plasma, tissue homogenates, and other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Applications
Competitive ELISA
Reactivity
Universal
Sensitivity
0.094 pmol/ml
Product range
0.156-10 pmol/ml
Assay Time
2 hours
Principiul testului
Universal Poly (ADP-Ribose) Polymer ELISA Kit (A303880) is a 2 hour competitive Enzyme-Linked Immunosorbent Assay (cELISA) designed for the in vitro quantitative determination of universal Poly (ADP-Ribose) Polymer in serum, plasma, tissue homogenates, and other biological fluids. A 96-well microtiter plate has been pre-coated with Poly (ADP-Ribose) Polymer. During the assay, Poly (ADP-Ribose) Polymer present in the standards or samples competes with immobilized Poly (ADP-Ribose) Polymer for binding to an assay-specific antibody. Following incubation, unbound components are removed by washing and HRP-Streptavidin conjugate is added to the wells. After further incubation and washing, TMB substrate solution is added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the colour is measured at 450 nm using a microplate reader. The concentration of Poly (ADP-Ribose) Polymer in the samples is inversely proportional to the OD450 value and is determined by comparison with the standard curve.