Sari la conținut
Coșul meu

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Sheep Luteinizing Hormone ELISA Kit

Pe scurt

Sheep Luteinizing Hormone ELISA Kit este un kit ELISA de tip Competitive (quantitative) pentru măsurarea Luteinizing Hormone, cu reactivitate declarată pentru Sheep. Măsoară în domeniul 0.938-60 mIU/ml, are o sensibilitate de 0.563 mIU/ml, folosește detecție Colorimetric Detection (OD450) și se poate folosi pe probe de tip Serum, plasma, tissue homogenates, and other biological fluids. Se livrează în mărimea 96T, la prețul de 4.625,23 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Sheep Luteinizing Hormone ELISA Kit is a competitive Enzyme-Linked Immunosorbent Assay (cELISA) designed for the in vitro quantitative determination of sheep Luteinizing Hormone in serum, plasma, tissue homogenates, and other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Applications
Competitive ELISA
Reactivity
Sheep
Sensitivity
0.563 mIU/ml
Product range
0.938-60 mIU/ml
Assay Time
2 hours
Principiul testului
Sheep Luteinizing Hormone ELISA Kit (A79834) is a 2 hour competitive Enzyme-Linked Immunosorbent Assay (cELISA) designed for the in vitro quantitative determination of sheep Luteinizing Hormone in serum, plasma, tissue homogenates, and other biological fluids. A 96-well microtiter plate has been pre-coated with Luteinizing Hormone. During the assay, Luteinizing Hormone present in the standards or samples competes with immobilized Luteinizing Hormone for binding to an assay-specific antibody. Following incubation, unbound components are removed by washing and HRP-Streptavidin conjugate is added to the wells. After further incubation and washing, TMB substrate solution is added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the colour is measured at 450 nm using a microplate reader. The concentration of Luteinizing Hormone in the samples is inversely proportional to the OD450 value and is determined by comparison with the standard curve.

Documentație

Produse similare

Ai nevoie de ajutor?

Nu găsești produsul potrivit? Scrie-ne cerințele și îți răspundem cu o recomandare și un preț.

Solicită consultanță

Achiziții publice

Suntem înregistrați în SEAP și livrăm către instituții publice, cu documentație completă.

Cum cumperi prin SEAP →

Contact