Sari la conținut
Coșul meu

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Bovine Luteinizing Hormone ELISA Kit

Pe scurt

Bovine Luteinizing Hormone ELISA Kit este un kit ELISA de tip Competitive (quantitative) pentru măsurarea Luteinizing Hormone, cu reactivitate declarată pentru Bovine. Măsoară în domeniul 1.563-100 mIU/ml, are o sensibilitate de 0.938 mIU/ml, folosește detecție Colorimetric Detection (OD450) și se poate folosi pe probe de tip Serum, plasma, tissue homogenates, and other biological fluids. Se livrează în mărimea 96T, la prețul de 4.625,23 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Bovine Luteinizing Hormone ELISA Kit is a competitive Enzyme-Linked Immunosorbent Assay (cELISA) designed for the in vitro quantitative determination of bovine Luteinizing Hormone in serum, plasma, tissue homogenates, and other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Applications
Competitive ELISA
Reactivity
Bovine
Sensitivity
0.938 mIU/ml
Product range
1.563-100 mIU/ml
Assay Time
2 hours
Principiul testului
Bovine Luteinizing Hormone ELISA Kit (A87479) is a 2 hour competitive Enzyme-Linked Immunosorbent Assay (cELISA) designed for the in vitro quantitative determination of bovine Luteinizing Hormone in serum, plasma, tissue homogenates, and other biological fluids. A 96-well microtiter plate has been pre-coated with Luteinizing Hormone. During the assay, Luteinizing Hormone present in the standards or samples competes with immobilized Luteinizing Hormone for binding to an assay-specific antibody. Following incubation, unbound components are removed by washing and HRP-Streptavidin conjugate is added to the wells. After further incubation and washing, TMB substrate solution is added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the colour is measured at 450 nm using a microplate reader. The concentration of Luteinizing Hormone in the samples is inversely proportional to the OD450 value and is determined by comparison with the standard curve.

Documentație