Imagine indisponibilăPorcine Acylated Ghrelin ELISA Kit
Pe scurt
Porcine Acylated Ghrelin ELISA Kit este un kit ELISA de tip Competitive (quantitative) pentru măsurarea Acylated Ghrelin, cu reactivitate declarată pentru Porcine. Măsoară în domeniul 0.313-20 ng/ml, are o sensibilitate de 0.188 ng/ml, folosește detecție Colorimetric Detection (OD450) și se poate folosi pe probe de tip Serum, plasma, tissue homogenates, and other biological fluids. Se livrează în mărimea 96T, la prețul de 5.091,08 lei cu TVA.
Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.
Descriere
Porcine Acylated Ghrelin ELISA Kit is a competitive Enzyme-Linked Immunosorbent Assay (cELISA) designed for the in vitro quantitative determination of porcine Acylated Ghrelin in serum, plasma, tissue homogenates, and other biological fluids.
Citește mai multArată mai puțin
Specificații
- Brand
- Antibodies
- Mărime
- 96T
- Țintă
- Acylated Ghrelin
- Applications
- Competitive ELISA
- Reactivity
- Porcine
- Assay type
- Competitive (quantitative)
- Sensitivity
- 0.188 ng/ml
- Cross reactivity
- Specific for Acylated Ghrelin with no reported cross-reactivity with other analogs or variants.
- Detection type
- Colorimetric Detection (OD450)
- Product range
- 0.313-20 ng/ml
- Assay Time
- 2 hours
- Principiul testului
- Porcine Acylated Ghrelin ELISA Kit (A247163) is a 2 hour competitive Enzyme-Linked Immunosorbent Assay (cELISA) designed for the in vitro quantitative determination of porcine Acylated Ghrelin in serum, plasma, tissue homogenates, and other biological fluids. A 96-well microtiter plate has been pre-coated with Acylated Ghrelin. During the assay, Acylated Ghrelin present in the standards or samples competes with immobilized Acylated Ghrelin for binding to an assay-specific antibody. Following incubation, unbound components are removed by washing and HRP-Streptavidin conjugate is added to the wells. After further incubation and washing, TMB substrate solution is added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the colour is measured at 450 nm using a microplate reader. The concentration of Acylated Ghrelin in the samples is inversely proportional to the OD450 value and is determined by comparison with the standard curve.
Documentație
Produse similare
Imagine indisponibilă
Imagine indisponibilă
Imagine indisponibilă
Imagine indisponibilă
Imagine indisponibilă
Imagine indisponibilă
Imagine indisponibilă
Imagine indisponibilă
Imagine indisponibilă
Imagine indisponibilă
Imagine indisponibilă
Imagine indisponibilă