Imagine indisponibilăHuman Anti-GRP78 BiP ELISA Kit
Pe scurt
Human Anti-GRP78 BiP ELISA Kit este un kit ELISA de tip Indirect (quantitative) pentru măsurarea Anti-GRP78 BiP, cu reactivitate declarată pentru Human. Măsoară în domeniul 0.391-25 ng/ml, are o sensibilitate de 0.234 ng/ml, folosește detecție Colorimetric Detection (OD450) și se poate folosi pe probe de tip Serum, plasma, tissue homogenates, and other biological fluids. Se livrează în mărimea 96T, la prețul de 4.392,30 lei cu TVA.
Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.
Descriere
Human Anti-GRP78 BiP ELISA Kit is an indirect Enzyme-Linked Immunosorbent Assay (iELISA) designed for the in vitro quantitative determination of human Anti-GRP78 BiP in serum, plasma, tissue homogenates, and other biological fluids.
Citește mai multArată mai puțin
Specificații
- Brand
- Antibodies
- Mărime
- 96T
- Țintă
- Anti-GRP78 BiP
- Applications
- Indirect ELISA
- Reactivity
- Human
- Assay type
- Indirect (quantitative)
- Sensitivity
- 0.234 ng/ml
- Cross reactivity
- Demonstrates specificity for anti-GRP78 BiP antibodies with no reported cross-reactivity to related analogs.
- Detection type
- Colorimetric Detection (OD450)
- Product range
- 0.391-25 ng/ml
- Assay Time
- 3 hours
- Principiul testului
- Human Anti-GRP78 BiP Antibody ELISA Kit (A247158) is a 3 hour indirect Enzyme-Linked Immunosorbent Assay (iELISA) designed for the in vitro quantitative determination of human Anti-GRP78 BiP Antibody in serum, plasma, tissue homogenates, and other biological fluids. A 96-well microtiter plate has been pre-coated with assay-specific antigen. Standards and samples are added to the wells, where Anti-GRP78 BiP Antibody binds to the immobilized antigen. Following incubation, unbound components are removed by washing and an enzyme-conjugated detection antibody is added to the wells. This detection antibody binds the captured Anti-GRP78 BiP Antibody to form an indirect immune complex. After further incubation and washing, TMB substrate solution is added to visualize the enzyme-mediated reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the yellow colour is directly proportional to the amount of Anti-GRP78 BiP Antibody present in the sample. The concentration of Anti-GRP78 BiP Antibody is calculated by reading the absorbance at 450 nm and comparing the values with the standard curve.
Produse similare
Imagine indisponibilă
Imagine indisponibilă
Imagine indisponibilă
Imagine indisponibilă
Imagine indisponibilă
Imagine indisponibilă
Imagine indisponibilă
Imagine indisponibilă
Imagine indisponibilă
Imagine indisponibilă
Imagine indisponibilă
Imagine indisponibilă