Sari la conținut
Coșul meu

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Human Fibrinogen alpha Chain ELISA Kit

Pe scurt

Human Fibrinogen alpha Chain ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea Fibrinogen alpha Chain, cu reactivitate declarată pentru Human. Măsoară în domeniul 3.12-200 ng/ml, are o sensibilitate de 1.13 ng/ml, folosește detecție Colourmetric și se poate folosi pe probe de tip Plasma or other biological fluids. Se livrează în mărimile 48T și 96T, la prețuri între 4.092,83 și 5.357,28 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human Fibrinogen alpha Chain ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human Fibrinogen alpha Chain in plasma or other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărimi disponibile
48T · 96T
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
1.13 ng/ml
Detection type
Colourmetric
Product range
3.12-200 ng/ml
Assay Time
4h 30m
Principiul testului
Human Fibrinogen alpha Chain ELISA Kit (A2231) employs the sandwich enzyme immunoassay technique for the quantitative measurement of human Fibrinogen alpha Chain in plasma or other biological fluids. An antibody specific for Fibrinogen alpha Chain has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the Fibrinogen alpha Chain present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-Fibrinogen alpha Chain Antibody, which binds the captured Fibrinogen alpha Chain present in each well. HRP-Avidin conjugate is then added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of Fibrinogen alpha Chain captured in each well. The concentration of Fibrinogen alpha Chain can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.

Documentație

Produse similare

Ai nevoie de ajutor?

Nu găsești produsul potrivit? Scrie-ne cerințele și îți răspundem cu o recomandare și un preț.

Solicită consultanță

Achiziții publice

Suntem înregistrați în SEAP și livrăm către instituții publice, cu documentație completă.

Cum cumperi prin SEAP →

Contact