Sari la conținut
Coșul meu

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Human FGFBP2 ELISA Kit

Pe scurt

Human FGFBP2 ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea FGFBP2, cu reactivitate declarată pentru Human. Măsoară în domeniul 1.56 - 100 ng/ml, are o sensibilitate de 0.94 ng/ml, folosește detecție Colorimetric Detection (OD450) și se poate folosi pe probe de tip Serum, plasma and other biological fluids. Se livrează în mărimea 96T, la prețul de 3.826,63 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human FGFBP2 ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay designed for the in vitro quantitative determination of human FGFBP2 in serum, plasma, and other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Țintă
FGFBP2
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
0.94 ng/ml
Product range
1.56 - 100 ng/ml
Assay Time
3h 30m
Principiul testului
Human FGFBP2 ELISA Kit (A327010) employs the sandwich enzyme immunoassay technique for the quantitative measurement of human FGFBP2 in serum, plasma, and other biological fluids. An antibody specific for FGFBP2 has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the FGFBP2 present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-FGFBP2 Antibody, which binds the captured FGFBP2 present in each well. Following incubation, unbound biotinylated detection antibody is removed by washing, and an HRP-Streptavidin conjugate is added to the wells and the microtiter plate is incubated. Following incubation and washing, substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of FGFBP2 captured in each well. The concentration of FGFBP2 can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.

Produse similare

Ai nevoie de ajutor?

Nu găsești produsul potrivit? Scrie-ne cerințele și îți răspundem cu o recomandare și un preț.

Solicită consultanță

Achiziții publice

Suntem înregistrați în SEAP și livrăm către instituții publice, cu documentație completă.

Cum cumperi prin SEAP →

Contact