Human APOA4 ELISA Kit

Pe scurt

Human APOA4 ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea APOA4, cu reactivitate declarată pentru Human. Măsoară în domeniul 1.56 - 100 ng/ml, are o sensibilitate de 0.26 ng/ml, folosește detecție Colorimetric și se poate folosi pe probe de tip Serum, plasma, tissue homogenates, cell culture supernates and other biological fluids. Se livrează în mărimea 96T, la prețul de 4.225,93 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human APOA4 ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human APOA4 in serum, plasma, tissue homogenates, cell culture supernates and other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Țintă
APOA4
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
0.26 ng/ml
Detection type
Colorimetric
Product range
1.56 - 100 ng/ml
Assay Time
4 hours
Principiul testului
Human APOA4 ELISA Kit (A119681) employs the sandwich enzyme immunoassay technique for the quantitative measurement of human APOA4 in serum, plasma, tissue homogenates, cell culture supernates and other biological fluids. An antibody specific for APOA4 has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the APOA4 present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-APOA4 Antibody, which binds the captured APOA4 present in each well. Following incubation, unbound biotinylated detection antibody is removed by washing, and an HRP-Streptavidin conjugate is added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of APOA4 captured in each well. The concentration of APOA4 can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.