Sari la conținut
Coșul meu

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Reverse Triiodothyronine ELISA Kit

Pe scurt

Reverse Triiodothyronine ELISA Kit este un kit ELISA de tip Competitive (quantitative) pentru măsurarea Reverse Triiodothyronine, cu reactivitate declarată pentru Universal. Măsoară în domeniul 93.8-6,000 pg/ml, are o sensibilitate de 24.32 pg/ml, folosește detecție Colourmetric și se poate folosi pe probe de tip Serum, plasma or other biological fluids. Se livrează în mărimile 48T și 96T, la prețuri între 4.225,93 și 5.457,10 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Reverse Triiodothyronine ELISA Kit is a competitive Enzyme-Linked Immunosorbent Assay (cELISA) designed for the in vitro quantitative determination of Reverse Triiodothyronine in serum, plasma or other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărimi disponibile
48T · 96T
Applications
Competitive ELISA
Reactivity
Universal
Sensitivity
24.32 pg/ml
Detection type
Colourmetric
Product range
93.8-6,000 pg/ml
Assay Time
2h 30m
Principiul testului
Reverse Triiodothyronine ELISA Kit (A3809) employs the competitive enzyme immunoassay technique for the quantitative measurement of Reverse Triiodothyronine in serum, plasma or other biological fluids. The 96-well microtiter plate has been pre-coated with Reverse Triiodothyronine antigen. During the incubation, Reverse Triiodothyronine present in the samples or standards competes with the fixed amount of immobilized Reverse Triiodothyronine for binding sites on the Biotinylated Anti-Reverse Triiodothyronine Antibody. The more Reverse Triiodothyronine present in a sample or standard, the less Biotinylated Anti-Reverse Triiodothyronine Antibody that binds to the plate. Following incubation, unbound Biotinylated Anti-Reverse Triiodothyronine Antibody is removed by washing, and an HRP-Avidin conjugate is added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is inversely proportional to the amount of Reverse Triiodothyronine present in each sample or standard. The concentration of Reverse Triiodothyronine can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.

Documentație

Produse similare

Ai nevoie de ajutor?

Nu găsești produsul potrivit? Scrie-ne cerințele și îți răspundem cu o recomandare și un preț.

Solicită consultanță

Achiziții publice

Suntem înregistrați în SEAP și livrăm către instituții publice, cu documentație completă.

Cum cumperi prin SEAP →

Contact