Imagine indisponibilăRat Testosterone ELISA Kit
Pe scurt
Rat Testosterone ELISA Kit este un kit ELISA de tip Competitive (quantitative) pentru măsurarea Testosterone, cu reactivitate declarată pentru Rat. Măsoară în domeniul 31.25 - 2000 pg/ml, are o sensibilitate de 18.75 pg/ml și folosește detecție Colorimetric Detection (OD450). Se livrează în mărimea 96T, la prețul de 3.993,00 lei cu TVA.
Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.
Descriere
Rat Testosterone ELISA Kit is a competitive Enzyme-Linked Immunosorbent Assay (cELISA) designed for the in vitro quantitative determination of rat Testosterone in serum, plasma, cell culture supernatant, cell or tissue lysate, and other liquid samples.
Citește mai multArată mai puțin
Specificații
- Brand
- Antibodies
- Mărime
- 96T
- Țintă
- Testosterone
- Applications
- Competitive ELISA
- Reactivity
- Rat
- Assay type
- Competitive (quantitative)
- Sensitivity
- 18.75 pg/ml
- Sample type
- Serum, plasma, cell culture supernatant, cell or tissue lysate, and other biological fluids.
- Cross reactivity
- Specific for Testosterone with no reported cross-reactivity with other analogs or variants.
- Detection type
- Colorimetric Detection (OD450)
- Product range
- 31.25 - 2000 pg/ml
- Assay Time
- 2 hours
- Principiul testului
- Rat Testosterone ELISA Kit (High Sensitivity) (A326906) is a 2 hour competitive Enzyme-Linked Immunosorbent Assay (cELISA) designed for the in vitro quantitative determination of rat Testosterone in serum, plasma, cell culture supernatant, cell or tissue lysate, and other biological fluids. A 96-well microtiter plate has been pre-coated with Testosterone. During the assay, Testosterone present in the standards or samples competes with immobilized Testosterone for binding to an assay-specific antibody. Following incubation, unbound components are removed by washing and HRP-Streptavidin conjugate is added to the wells. After further incubation and washing, TMB substrate solution is added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the colour is measured at 450 nm using a microplate reader. The concentration of Testosterone in the samples is inversely proportional to the OD450 value and is determined by comparison with the standard curve.