Rat PD-L1 ELISA Kit

Pe scurt

Rat PD-L1 ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea PD-L1, cu reactivitate declarată pentru Rat. Măsoară în domeniul 78.125-5000 pg/ml, are o sensibilitate de 46.875 pg/ml, folosește detecție Colorimetric Detection (OD450) și se poate folosi pe probe de tip Serum, plasma, tissue homogenates, and other biological fluids. Se livrează în mărimea 96T, la prețul de 4.392,30 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Rat PD-L1 ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of rat PD-L1 in serum, plasma, tissue homogenates, and other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Țintă
PD-L1
Applications
Sandwich ELISA
Reactivity
Rat
Sensitivity
46.875 pg/ml
Product range
78.125-5000 pg/ml
Assay Time
4 hours
Principiul testului
Rat PD-L1 ELISA Kit (A74927) is a 4 hour sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of rat PD-L1 in serum, plasma, tissue homogenates, and other biological fluids. A 96-well microtiter plate has been pre-coated with an antibody specific for PD-L1. Standards and samples are added to the wells, where PD-L1 binds to the immobilized capture antibody. Following incubation, unbound components are removed by washing and a biotinylated detection antibody specific for PD-L1 is added to the wells. The detection antibody binds the captured PD-L1 to form an antibody-antigen-antibody sandwich complex. After further incubation and washing, HRP-Streptavidin conjugate is added to the wells. TMB substrate solution is then added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the yellow colour is directly proportional to the amount of PD-L1 captured in each well. The concentration of PD-L1 is calculated by reading the absorbance at 450 nm and comparing the values with the standard curve.