Pe scurt
Rat GFM1 ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea GFM1, cu reactivitate declarată pentru Rat. Măsoară în domeniul 1.25-2000 pg/ml, are o sensibilitate de 18.75 pg/ml și folosește detecție Colorimetric Detection (OD450). Se livrează în mărimea 96T, la prețul de 3.746,77 lei cu TVA.
Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.
Descriere
Rat GFM1 ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of rat GFM1 in serum, plasma, cell culture supernatant, cell or tissue lysate, and other liquid samples.
Citește mai multArată mai puțin
Specificații
- Brand
- Antibodies
- Mărime
- 96T
- Țintă
- GFM1
- Applications
- Sandwich ELISA
- Reactivity
- Rat
- Assay type
- Sandwich (quantitative)
- Sensitivity
- 18.75 pg/ml
- Sample type
- Serum, plasma, cell culture supernatant, cell or tissue lysate, and other biological fluids.
- Detection type
- Colorimetric Detection (OD450)
- Product range
- 1.25-2000 pg/ml
- Assay Time
- 4 hours
- Principiul testului
- Rat GFM1 ELISA Kit (A335419) is a 4 hour sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of rat GFM1 in serum, plasma, cell culture supernatant, cell or tissue lysate, and other biological fluids. A 96-well microtiter plate has been pre-coated with an antibody specific for GFM1. Standards and samples are added to the wells, where GFM1 binds to the immobilized capture antibody. Following incubation, unbound components are removed by washing and a biotinylated detection antibody specific for GFM1 is added to the wells. The detection antibody binds the captured GFM1 to form an antibody-antigen-antibody sandwich complex. After further incubation and washing, HRP-Streptavidin conjugate is added to the wells. TMB substrate solution is then added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the yellow colour is directly proportional to the amount of GFM1 captured in each well. The concentration of GFM1 is calculated by reading the absorbance at 450 nm and comparing the values with the standard curve.