Rat CYP11A1 ELISA Kit

Pe scurt

Rat CYP11A1 ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea CYP11A1, cu reactivitate declarată pentru Rat. Măsoară în domeniul 15.625-1000 pg/ml, are o sensibilitate de 9.375 pg/ml, folosește detecție Colorimetric Detection (OD450) și se poate folosi pe probe de tip Serum, plasma, tissue homogenates, and other biological fluids. Se livrează în mărimea 96T, la prețul de 4.392,30 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Rat CYP11A1 ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of rat CYP11A1 in serum, plasma, tissue homogenates, and other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Țintă
CYP11A1
Applications
Sandwich ELISA
Reactivity
Rat
Sensitivity
9.375 pg/ml
Product range
15.625-1000 pg/ml
Assay Time
4 hours
Principiul testului
Rat CYP11A1 ELISA Kit (A87153) is a 4 hour sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of rat CYP11A1 in serum, plasma, tissue homogenates, and other biological fluids. A 96-well microtiter plate has been pre-coated with an antibody specific for CYP11A1. Standards and samples are added to the wells, where CYP11A1 binds to the immobilized capture antibody. Following incubation, unbound components are removed by washing and a biotinylated detection antibody specific for CYP11A1 is added to the wells. The detection antibody binds the captured CYP11A1 to form an antibody-antigen-antibody sandwich complex. After further incubation and washing, HRP-Streptavidin conjugate is added to the wells. TMB substrate solution is then added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the yellow colour is directly proportional to the amount of CYP11A1 captured in each well. The concentration of CYP11A1 is calculated by reading the absorbance at 450 nm and comparing the values with the standard curve.