Rabbit Osteocalcin ELISA Kit

Pe scurt

Rabbit Osteocalcin ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea Osteocalcin, cu reactivitate declarată pentru Rabbit. Măsoară în domeniul 15.625-1000 pg/ml, are o sensibilitate de 9.375 pg/ml, folosește detecție Colorimetric Detection (OD450) și se poate folosi pe probe de tip Serum, plasma, tissue homogenates, and other biological fluids. Se livrează în mărimea 96T, la prețul de 5.091,08 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Rabbit Osteocalcin ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of rabbit Osteocalcin in serum, plasma, tissue homogenates, and other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Applications
Sandwich ELISA
Reactivity
Rabbit
Sensitivity
9.375 pg/ml
Product range
15.625-1000 pg/ml
Assay Time
4 hours
Principiul testului
Rabbit Osteocalcin ELISA Kit (A74159) is a 4 hour sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of rabbit Osteocalcin in serum, plasma, tissue homogenates, and other biological fluids. A 96-well microtiter plate has been pre-coated with an antibody specific for Osteocalcin . Standards and samples are added to the wells, where Osteocalcin binds to the immobilized capture antibody. Following incubation, unbound components are removed by washing and a biotinylated detection antibody specific for Osteocalcin is added to the wells. The detection antibody binds the captured Osteocalcin to form an antibody-antigen-antibody sandwich complex. After further incubation and washing, HRP-Streptavidin conjugate is added to the wells. TMB substrate solution is then added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the yellow colour is directly proportional to the amount of Osteocalcin captured in each well. The concentration of Osteocalcin is calculated by reading the absorbance at 450 nm and comparing the values with the standard curve.