Rabbit OCT4 ELISA Kit

Pe scurt

Rabbit OCT4 ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea OCT4, cu reactivitate declarată pentru Rabbit. Măsoară în domeniul 0.156-10 ng/ml, are o sensibilitate de 0.094 ng/ml, folosește detecție Colorimetric Detection (OD450) și se poate folosi pe probe de tip Serum, plasma, tissue homogenates, and other biological fluids. Se livrează în mărimea 96T, la prețul de 5.091,08 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Rabbit OCT4 ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of rabbit OCT4 in serum, plasma, tissue homogenates, and other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Țintă
OCT4
Applications
Sandwich ELISA
Reactivity
Rabbit
Sensitivity
0.094 ng/ml
Product range
0.156-10 ng/ml
Assay Time
4 hours
Principiul testului
Rabbit OCT4 ELISA Kit (A74917) is a 4 hour sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of rabbit OCT4 in serum, plasma, tissue homogenates, and other biological fluids. A 96-well microtiter plate has been pre-coated with an antibody specific for OCT4. Standards and samples are added to the wells, where OCT4 binds to the immobilized capture antibody. Following incubation, unbound components are removed by washing and a biotinylated detection antibody specific for OCT4 is added to the wells. The detection antibody binds the captured OCT4 to form an antibody-antigen-antibody sandwich complex. After further incubation and washing, HRP-Streptavidin conjugate is added to the wells. TMB substrate solution is then added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the yellow colour is directly proportional to the amount of OCT4 captured in each well. The concentration of OCT4 is calculated by reading the absorbance at 450 nm and comparing the values with the standard curve.