Sari la conținut
Coșul meu

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Rabbit Angiotensin II ELISA Kit

Pe scurt

Rabbit Angiotensin II ELISA Kit este un kit ELISA de tip Competitive (quantitative) pentru măsurarea Angiotensin II, cu reactivitate declarată pentru Rabbit. Măsoară în domeniul 31.2-2000 pg/ml, are o sensibilitate de 9.66 pg/ml și folosește detecție Colourmetric. Se livrează în mărimile 48T și 96T, la prețuri între 3.826,63 și 4.891,43 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Rabbit Angiotensin II ELISA Kit is a competitive Enzyme-Linked Immunosorbent Assay (cELISA) designed for the in vitro quantitative determination of rabbit Angiotensin II in serum, plasma, tissue homogenates, cell lysates, cell culture supernates or other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărimi disponibile
48T · 96T
Applications
Competitive ELISA
Reactivity
Rabbit
Sensitivity
9.66 pg/ml
Detection type
Colourmetric
Product range
31.2-2000 pg/ml
Assay Time
2h 30m
Principiul testului
Rabbit Angiotensin II ELISA Kit (A5919) employs the competitive enzyme immunoassay technique for the quantitative measurement of rabbit Angiotensin II in serum, plasma, tissue homogenates, cell lysates, cell culture supernates or other biological fluids. The 96-well microtiter plate has been pre-coated with Angiotensin II antigen. During the incubation, Angiotensin II present in the samples or standards competes with the fixed amount of immobilized Angiotensin II for binding sites on the Biotinylated Anti-Angiotensin II Antibody. The more Angiotensin II present in a sample or standard, the less Biotinylated Anti-Angiotensin II Antibody that binds to the plate. Following incubation, unbound Biotinylated Anti-Angiotensin II Antibody is removed by washing, and an HRP-Avidin conjugate is added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is inversely proportional to the amount of Angiotensin II present in each sample or standard. The concentration of Angiotensin II can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.

Documentație