Porcine NF-L ELISA Kit

Pe scurt

Porcine NF-L ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea NF-L, cu reactivitate declarată pentru Porcine. Măsoară în domeniul 15.625-1000 pg/ml, are o sensibilitate de 9.375 pg/ml și folosește detecție Colorimetric Detection (OD450). Se livrează în mărimea 96T, la prețul de 4.625,23 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Porcine NF-L ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of porcine NF-L in serum, plasma, cell culture supernatant, cell or tissue lysate, and other liquid samples.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Țintă
NF-L
Applications
Sandwich ELISA
Reactivity
Porcine
Sensitivity
9.375 pg/ml
Product range
15.625-1000 pg/ml
Assay Time
4 hours
Principiul testului
Porcine NF-L ELISA Kit (A335326) is a 4 hour sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of porcine NF-L in serum, plasma, cell culture supernatant, cell or tissue lysate, and other biological fluids. A 96-well microtiter plate has been pre-coated with an antibody specific for NF-L. Standards and samples are added to the wells, where NF-L binds to the immobilized capture antibody. Following incubation, unbound components are removed by washing and a biotinylated detection antibody specific for NF-L is added to the wells. The detection antibody binds the captured NF-L to form an antibody-antigen-antibody sandwich complex. After further incubation and washing, HRP-Streptavidin conjugate is added to the wells. TMB substrate solution is then added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the yellow colour is directly proportional to the amount of NF-L captured in each well. The concentration of NF-L is calculated by reading the absorbance at 450 nm and comparing the values with the standard curve.