Sari la conținut
Coșul meu

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Porcine Corticotropin Releasing Hormone ELISA Kit

Pe scurt

Porcine Corticotropin Releasing Hormone ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea Corticotropin Releasing Hormone, cu reactivitate declarată pentru Porcine. Măsoară în domeniul 1.563-100 pg/ml, are o sensibilitate de 0.938 pg/ml, folosește detecție Colorimetric Detection (OD450) și se poate folosi pe probe de tip Serum, plasma, tissue homogenates, and other biological fluids. Se livrează în mărimea 96T, la prețul de 5.091,08 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Porcine Corticotropin Releasing Hormone ELISA Kit is a competitive Enzyme-Linked Immunosorbent Assay (cELISA) designed for the in vitro quantitative determination of porcine Corticotropin Releasing Hormone in serum, plasma, tissue homogenates, and other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Applications
Competitive ELISA
Reactivity
Porcine
Sensitivity
0.938 pg/ml
Product range
1.563-100 pg/ml
Assay Time
2 hours
Principiul testului
Porcine Corticotropin Releasing Hormone ELISA Kit (A75327) is a 2 hour competitive Enzyme-Linked Immunosorbent Assay (cELISA) designed for the in vitro quantitative determination of porcine Corticotropin Releasing Hormone in serum, plasma, tissue homogenates, and other biological fluids. A 96-well microtiter plate has been pre-coated with Corticotropin Releasing Hormone. During the assay, Corticotropin Releasing Hormone present in the standards or samples competes with immobilized Corticotropin Releasing Hormone for binding to an assay-specific antibody. Following incubation, unbound components are removed by washing and HRP-Streptavidin conjugate is added to the wells. After further incubation and washing, TMB substrate solution is added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the colour is measured at 450 nm using a microplate reader. The concentration of Corticotropin Releasing Hormone in the samples is inversely proportional to the OD450 value and is determined by comparison with the standard curve.

Documentație

Produse similare

Ai nevoie de ajutor?

Nu găsești produsul potrivit? Scrie-ne cerințele și îți răspundem cu o recomandare și un preț.

Solicită consultanță

Achiziții publice

Suntem înregistrați în SEAP și livrăm către instituții publice, cu documentație completă.

Cum cumperi prin SEAP →

Contact