Sari la conținut
Coșul meu

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

PLC beta 3 (phospho Ser537) Cell Based ELISA Kit

Pe scurt

PLC beta 3 (phospho Ser537) Cell Based ELISA Kit este un kit ELISA de tip Cell-based (qualitative) pentru măsurarea PLCB3, cu reactivitate declarată pentru Human (Ser537), Mouse (Ser537), Rat (Ser535). Măsoară în domeniul > 5000 Cells, folosește detecție Colorimetric și se poate folosi pe probe de tip Adherent and suspension cells. Se livrează în mărimea 2 x 96T, la prețul de 4.625,23 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

PLC beta 3 (phospho Ser537) Cell Based ELISA Kit is a Enzyme-Linked Immunosorbent Assay designed for the indirect in vitro quantitative determination of PLCB3 levels in adherent and suspension cells.

Citește mai multArată mai puțin

Specificații

Mărime
2 x 96T
Țintă
PLCB3
Applications
Cell-Based ELISA
Detection type
Colorimetric
Product range
> 5000 Cells
Principiul testului
This PLC beta 3 (phospho Ser537) Cell-Based ELISA Kit allows for the detection of PLC beta 3 (phospho Ser537) and the effects that certain stimulation conditions have on PLC beta 3 (phospho Ser537) expression in different cell lines. Qualitative determination of PLC beta 3 (phospho Ser537) concentration is achieved by an indirect ELISA format. In essence, the PLC beta 3 (phospho Ser537) is captured by Anti-PLC beta 3 (phospho Ser537) Antibodies which in turn are detected by HRP-conjugated secondary antibodies. Through this binding, the HRP enzyme (conjugated to the secondary antibody) can catalyze a colorimetric reaction upon substrate addition. Due to the qualitative nature of this PLC beta 3 (phospho Ser537) Cell-Based ELISA Kit, multiple normalization methods are described: 1) Anti-GAPDH Antibody is included to serve as an internal positive control in normalizing the target absorbance values. 2) Following the colorimetric measurement of HRP activity via substrate addition, the Crystal Violet whole-cell staining method is used to determine cell density. After staining, the results can be analyzed by normalizing the absorbance values to cell amounts, by which the plating difference can be adjusted. 3) Anti-PLC beta 3 Antibody is provided for normalization purposes. The absorbance values obtained for the non-phosphorylated target can be used to normalize the absorbance values for the phosphorylated target.

Produse similare

Ai nevoie de ajutor?

Nu găsești produsul potrivit? Scrie-ne cerințele și îți răspundem cu o recomandare și un preț.

Solicită consultanță

Achiziții publice

Suntem înregistrați în SEAP și livrăm către instituții publice, cu documentație completă.

Cum cumperi prin SEAP →

Contact