Sari la conținut
Coșul meu

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Mouse TGE ELISA Kit

Pe scurt

Mouse TGE ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea TGE, cu reactivitate declarată pentru Mouse. Măsoară în domeniul 0.625-40 ng/ml, are o sensibilitate de 0.255 ng/ml, folosește detecție Colourmetric și se poate folosi pe probe de tip Serum, plasma, tissue homogenates or other biological fluids. Se livrează în mărimile 48T și 96T, la prețuri între 4.225,93 și 5.457,10 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Mouse TGE ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of mouse TGE in serum, plasma, tissue homogenates or other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărimi disponibile
48T · 96T
Țintă
TGE
Applications
Sandwich ELISA
Reactivity
Mouse
Sensitivity
0.255 ng/ml
Detection type
Colourmetric
Product range
0.625-40 ng/ml
Assay Time
4h 30m
Principiul testului
Mouse TGE ELISA Kit (A6541) employs the sandwich enzyme immunoassay technique for the quantitative measurement of mouse TGE in serum, plasma, tissue homogenates or other biological fluids. An antibody specific for TGE has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the TGE present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-TGE Antibody, which binds the captured TGE present in each well. HRP-Avidin conjugate is then added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of TGE captured in each well. The concentration of TGE can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.

Documentație

Produse similare

Ai nevoie de ajutor?

Nu găsești produsul potrivit? Scrie-ne cerințele și îți răspundem cu o recomandare și un preț.

Solicită consultanță

Achiziții publice

Suntem înregistrați în SEAP și livrăm către instituții publice, cu documentație completă.

Cum cumperi prin SEAP →

Contact