Sari la conținut
Coșul meu

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Mouse PVRL1/NECTIN1 ELISA Kit

Pe scurt

Mouse PVRL1/NECTIN1 ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea PVRL1/NECTIN1, cu reactivitate declarată pentru Mouse. Măsoară în domeniul 0.156-10 ng/ml, are o sensibilitate de 0.094 ng/ml, folosește detecție Colorimetric Detection (OD450) și se poate folosi pe probe de tip Serum, plasma, tissue homogenates, and other biological fluids. Se livrează în mărimea 96T, la prețul de 4.392,30 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Mouse PVRL1/NECTIN1 ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of mouse PVRL1/NECTIN1 in serum, plasma, tissue homogenates, and other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Applications
Sandwich ELISA
Reactivity
Mouse
Sensitivity
0.094 ng/ml
Product range
0.156-10 ng/ml
Assay Time
4 hours
Principiul testului
Mouse PVRL1/NECTIN1 ELISA Kit (A77224) is a 4 hour sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of mouse PVRL1/NECTIN1 in serum, plasma, tissue homogenates, and other biological fluids. A 96-well microtiter plate has been pre-coated with an antibody specific for PVRL1/NECTIN1. Standards and samples are added to the wells, where PVRL1/NECTIN1 binds to the immobilized capture antibody. Following incubation, unbound components are removed by washing and a biotinylated detection antibody specific for PVRL1/NECTIN1 is added to the wells. The detection antibody binds the captured PVRL1/NECTIN1 to form an antibody-antigen-antibody sandwich complex. After further incubation and washing, HRP-Streptavidin conjugate is added to the wells. TMB substrate solution is then added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the yellow colour is directly proportional to the amount of PVRL1/NECTIN1 captured in each well. The concentration of PVRL1/NECTIN1 is calculated by reading the absorbance at 450 nm and comparing the values with the standard curve.

Documentație

Produse similare

Ai nevoie de ajutor?

Nu găsești produsul potrivit? Scrie-ne cerințele și îți răspundem cu o recomandare și un preț.

Solicită consultanță

Achiziții publice

Suntem înregistrați în SEAP și livrăm către instituții publice, cu documentație completă.

Cum cumperi prin SEAP →

Contact