Sari la conținut
Coșul meu

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Mouse MADH7/SMAD7 ELISA Kit

Pe scurt

Mouse MADH7/SMAD7 ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea MADH7/SMAD7, cu reactivitate declarată pentru Mouse. Măsoară în domeniul 0.313-20 ng/ml, are o sensibilitate de 0.188 ng/ml, folosește detecție Colorimetric Detection (OD450) și se poate folosi pe probe de tip Serum, plasma, tissue homogenates, and other biological fluids. Se livrează în mărimea 96T, la prețul de 4.392,30 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Mouse MADH7/SMAD7 ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of mouse MADH7/SMAD7 in serum, plasma, tissue homogenates, and other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Applications
Sandwich ELISA
Reactivity
Mouse
Sensitivity
0.188 ng/ml
Product range
0.313-20 ng/ml
Assay Time
4 hours
Principiul testului
Mouse MADH7/SMAD7 ELISA Kit (A77344) is a 4 hour sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of mouse MADH7/SMAD7 in serum, plasma, tissue homogenates, and other biological fluids. A 96-well microtiter plate has been pre-coated with an antibody specific for MADH7/SMAD7. Standards and samples are added to the wells, where MADH7/SMAD7 binds to the immobilized capture antibody. Following incubation, unbound components are removed by washing and a biotinylated detection antibody specific for MADH7/SMAD7 is added to the wells. The detection antibody binds the captured MADH7/SMAD7 to form an antibody-antigen-antibody sandwich complex. After further incubation and washing, HRP-Streptavidin conjugate is added to the wells. TMB substrate solution is then added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the yellow colour is directly proportional to the amount of MADH7/SMAD7 captured in each well. The concentration of MADH7/SMAD7 is calculated by reading the absorbance at 450 nm and comparing the values with the standard curve.

Documentație

Produse similare

Ai nevoie de ajutor?

Nu găsești produsul potrivit? Scrie-ne cerințele și îți răspundem cu o recomandare și un preț.

Solicită consultanță

Achiziții publice

Suntem înregistrați în SEAP și livrăm către instituții publice, cu documentație completă.

Cum cumperi prin SEAP →

Contact