Mouse LDHD/DLD ELISA Kit

Pe scurt

Mouse LDHD/DLD ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea LDHD/DLD, cu reactivitate declarată pentru Mouse. Măsoară în domeniul 4.688-300 mIU/ml, are o sensibilitate de 2.813 mIU/ml, folosește detecție Colorimetric Detection (OD450) și se poate folosi pe probe de tip Serum, plasma, tissue homogenates, and other biological fluids. Se livrează în mărimea 96T, la prețul de 4.591,95 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Mouse LDHD/DLD ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of mouse LDHD/DLD in serum, plasma, tissue homogenates, and other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Țintă
LDHD/DLD
Applications
Sandwich ELISA
Reactivity
Mouse
Sensitivity
2.813 mIU/ml
Product range
4.688-300 mIU/ml
Assay Time
4 hours
Principiul testului
Mouse LDHD/DLD ELISA Kit (A303387) is a 4 hour sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of mouse LDHD/DLD in serum, plasma, tissue homogenates, and other biological fluids. A 96-well microtiter plate has been pre-coated with an antibody specific for LDHD/DLD. Standards and samples are added to the wells, where LDHD/DLD binds to the immobilized capture antibody. Following incubation, unbound components are removed by washing and a biotinylated detection antibody specific for LDHD/DLD is added to the wells. The detection antibody binds the captured LDHD/DLD to form an antibody-antigen-antibody sandwich complex. After further incubation and washing, HRP-Streptavidin conjugate is added to the wells. TMB substrate solution is then added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the yellow colour is directly proportional to the amount of LDHD/DLD captured in each well. The concentration of LDHD/DLD is calculated by reading the absorbance at 450 nm and comparing the values with the standard curve.