Mouse HMGCR ELISA Kit

Pe scurt

Mouse HMGCR ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea HMGCR, cu reactivitate declarată pentru Mouse. Măsoară în domeniul 0.781-50 ng/ml, are o sensibilitate de 0.31 ng/ml, folosește detecție Colourmetric și se poate folosi pe probe de tip Tissue homogenates, cell lysates or other biological fluids. Se livrează în mărimile 48T și 96T, la prețuri între 6.089,33 și 8.618,23 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Mouse HMGCR ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of mouse HMGCR in tissue homogenates, cell lysates or other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărimi disponibile
48T · 96T
Țintă
HMGCR
Applications
Sandwich ELISA
Reactivity
Mouse
Sensitivity
0.31 ng/ml
Detection type
Colourmetric
Product range
0.781-50 ng/ml
Assay Time
4h 30m
Principiul testului
Mouse HMGCR ELISA Kit (A270901) employs the sandwich enzyme immunoassay technique for the quantitative measurement of mouse HMGCR in tissue homogenates, cell lysates or other biological fluids. An antibody specific for HMGCR has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the HMGCR present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-HMGCR Antibody, which binds the captured HMGCR present in each well. HRP-Avidin conjugate is then added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of HMGCR captured in each well. The concentration of HMGCR can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.