Imagine indisponibilăMouse HbA1C ELISA Kit
Pe scurt
Mouse HbA1C ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea HbA1c, cu reactivitate declarată pentru Mouse. Măsoară în domeniul 1.25-80 ng/ml, are o sensibilitate de 0.75 ng/ml, folosește detecție Colorimetric Detection (OD450) și se poate folosi pe probe de tip Red blood cell lysates and other biological samples. Se livrează în mărimea 96T, la prețul de 4.186,00 lei cu TVA.
Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.
Descriere
Mouse HbA1C ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of mouse HbA1C in red blood cell lysis and other biological samples
Citește mai multArată mai puțin
Specificații
- Brand
- Antibodies
- Mărime
- 96T
- Țintă
- HbA1c
- Applications
- Sandwich ELISA
- Reactivity
- Mouse
- Recommended dilutions
- Validated sample dilutions include Healthy whole blood (1:50-1:250) and Red blood cell lysate (1:2-1:5).
- Assay type
- Sandwich (quantitative)
- Sensitivity
- 0.75 ng/ml
- Cross reactivity
- Specific for HbA1C with no reported cross-reactivity with other analogs or variants.
- Detection type
- Colorimetric Detection (OD450)
- Product range
- 1.25-80 ng/ml
- Assay Time
- 2 hours
- Principiul testului
- Mouse HbA1C ELISA Kit (A336465) is a 2 hour sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of mouse HbA1C in red blood cell lysates and other biological samples. This QuickRun format uses a pre-coated 96-well microtiter plate and optimized ready-to-use reagents to reduce assay time. Standards and samples are added to the wells, where HbA1C binds to the immobilized capture antibody. Assay-specific biotinylated detection antibody and HRP-Streptavidin reagents are then added according to the optimized QuickRun workflow. These reagents form an antibody-antigen-antibody sandwich complex with the captured HbA1C. TMB substrate solution is added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the yellow colour is directly proportional to the amount of HbA1C captured in each well. The concentration of HbA1C is calculated by reading the absorbance at 450 nm and comparing the values with the standard curve.