Mouse Enkephalin/ENK ELISA Kit

Pe scurt

Mouse Enkephalin/ENK ELISA Kit este un kit ELISA de tip Competitive (quantitative) pentru măsurarea Enkephalin/ENK, cu reactivitate declarată pentru Mouse. Măsoară în domeniul 93.8-6,000 pg/ml, are o sensibilitate de 25.35 pg/ml, folosește detecție Colourmetric și se poate folosi pe probe de tip Serum, plasma or other biological fluids. Se livrează în mărimile 48T și 96T, la prețuri între 4.225,93 și 5.457,10 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Mouse Enkephalin/ENK ELISA Kit is a competitive Enzyme-Linked Immunosorbent Assay (cELISA) designed for the in vitro quantitative determination of mouse Enkephalin/ENK in serum, plasma or other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărimi disponibile
48T · 96T
Applications
Competitive ELISA
Reactivity
Mouse
Sensitivity
25.35 pg/ml
Detection type
Colourmetric
Product range
93.8-6,000 pg/ml
Assay Time
2h 30m
Principiul testului
Mouse Enkephalin/ENK ELISA Kit (A3339) employs the competitive enzyme immunoassay technique for the quantitative measurement of mouse Enkephalin/ENK in serum, plasma or other biological fluids. The 96-well microtiter plate has been pre-coated with Enkephalin/ENK antigen. During the incubation, Enkephalin/ENK present in the samples or standards competes with the fixed amount of immobilized Enkephalin/ENK for binding sites on the Biotinylated Anti-Enkephalin/ENK Antibody. The more Enkephalin/ENK present in a sample or standard, the less Biotinylated Anti-Enkephalin/ENK Antibody that binds to the plate. Following incubation, unbound Biotinylated Anti-Enkephalin/ENK Antibody is removed by washing, and an HRP-Avidin conjugate is added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is inversely proportional to the amount of Enkephalin/ENK present in each sample or standard. The concentration of Enkephalin/ENK can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.