Mouse CD272/BTLA ELISA Kit

Pe scurt

Mouse CD272/BTLA ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea CD272/BTLA, cu reactivitate declarată pentru Mouse. Măsoară în domeniul 31.25 - 2000 pg/ml, are o sensibilitate de 18.75 pg/ml și folosește detecție Colorimetric Detection (OD450). Se livrează în mărimea 96T, la prețul de 3.993,00 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Mouse CD272/BTLA ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of mouse CD272/BTLA in serum, plasma, cell culture supernatant, cell or tissue lysate, and other liquid samples.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Țintă
CD272/BTLA
Applications
Sandwich ELISA
Reactivity
Mouse
Sensitivity
18.75 pg/ml
Product range
31.25 - 2000 pg/ml
Assay Time
4 hours
Principiul testului
Mouse CD272/BTLA ELISA Kit (A326431) is a 4 hour sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of mouse CD272/BTLA in serum, plasma, cell culture supernatant, cell or tissue lysate, and other biological fluids. A 96-well microtiter plate has been pre-coated with an antibody specific for CD272/BTLA. Standards and samples are added to the wells, where CD272/BTLA binds to the immobilized capture antibody. Following incubation, unbound components are removed by washing and a biotinylated detection antibody specific for CD272/BTLA is added to the wells. The detection antibody binds the captured CD272/BTLA to form an antibody-antigen-antibody sandwich complex. After further incubation and washing, HRP-Streptavidin conjugate is added to the wells. TMB substrate solution is then added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the yellow colour is directly proportional to the amount of CD272/BTLA captured in each well. The concentration of CD272/BTLA is calculated by reading the absorbance at 450 nm and comparing the values with the standard curve.