Mouse BMP1/PCP ELISA Kit

Pe scurt

Mouse BMP1/PCP ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea BMP1/PCP, cu reactivitate declarată pentru Mouse. Măsoară în domeniul 78.1-5000 pg/ml, are o sensibilitate de 30 pg/ml, folosește detecție Colourmetric și se poate folosi pe probe de tip Serum, plasma, tissue homogenates, cell lysates or other biological fluids. Se livrează în mărimile 48T și 96T, la prețuri între 3.993,00 și 5.290,73 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Mouse BMP1/PCP ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of mouse BMP1/PCP in serum, plasma, tissue homogenates, cell lysates or other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărimi disponibile
48T · 96T
Țintă
BMP1/PCP
Applications
Sandwich ELISA
Reactivity
Mouse
Sensitivity
30 pg/ml
Detection type
Colourmetric
Product range
78.1-5000 pg/ml
Assay Time
4h 30m
Principiul testului
Mouse BMP1/PCP ELISA Kit (A2375) employs the sandwich enzyme immunoassay technique for the quantitative measurement of mouse BMP1/PCP in serum, plasma, tissue homogenates, cell lysates or other biological fluids. An antibody specific for BMP1/PCP has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the BMP1/PCP present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-BMP1/PCP Antibody, which binds the captured BMP1/PCP present in each well. HRP-Avidin conjugate is then added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of BMP1/PCP captured in each well. The concentration of BMP1/PCP can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.