Sari la conținut
Coșul meu

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Monkey SOD2 ELISA Kit

Pe scurt

Monkey SOD2 ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea SOD2, cu reactivitate declarată pentru Monkey. Măsoară în domeniul 1.25-80 ng/ml, are o sensibilitate de 0.75 ng/ml și folosește detecție Colorimetric Detection (OD450). Se livrează în mărimea 96T, la prețul de 4.625,23 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Monkey SOD2 ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of monkey SOD2 in serum, plasma, cell culture supernatant, cell or tissue lysate, and other liquid samples.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Țintă
SOD2
Applications
Sandwich ELISA
Reactivity
Monkey
Sensitivity
0.75 ng/ml
Product range
1.25-80 ng/ml
Assay Time
4 hours
Principiul testului
Monkey SOD2 ELISA Kit (A335270) is a 4 hour sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of monkey SOD2 in serum, plasma, cell culture supernatant, cell or tissue lysate, and other biological fluids. A 96-well microtiter plate has been pre-coated with an antibody specific for SOD2. Standards and samples are added to the wells, where SOD2 binds to the immobilized capture antibody. Following incubation, unbound components are removed by washing and a biotinylated detection antibody specific for SOD2 is added to the wells. The detection antibody binds the captured SOD2 to form an antibody-antigen-antibody sandwich complex. After further incubation and washing, HRP-Streptavidin conjugate is added to the wells. TMB substrate solution is then added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the yellow colour is directly proportional to the amount of SOD2 captured in each well. The concentration of SOD2 is calculated by reading the absorbance at 450 nm and comparing the values with the standard curve.

Documentație

Produse similare

Ai nevoie de ajutor?

Nu găsești produsul potrivit? Scrie-ne cerințele și îți răspundem cu o recomandare și un preț.

Solicită consultanță

Achiziții publice

Suntem înregistrați în SEAP și livrăm către instituții publice, cu documentație completă.

Cum cumperi prin SEAP →

Contact