Monkey M-CSF ELISA Kit

Pe scurt

Monkey M-CSF ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea M-CSF, cu reactivitate declarată pentru Monkey. Măsoară în domeniul 15.625-1000 pg/ml, are o sensibilitate de 9.375 pg/ml și folosește detecție Colorimetric Detection (OD450). Se livrează în mărimea 96T, la prețul de 4.625,23 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Monkey M-CSF ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of monkey M-CSF in serum, plasma, cell culture supernatant, cell or tissue lysate, and other liquid samples.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Țintă
M-CSF
Applications
Sandwich ELISA
Reactivity
Monkey
Sensitivity
9.375 pg/ml
Product range
15.625-1000 pg/ml
Assay Time
4 hours
Principiul testului
Monkey M-CSF ELISA Kit (A335294) is a 4 hour sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of monkey M-CSF in serum, plasma, cell culture supernatant, cell or tissue lysate, and other biological fluids. A 96-well microtiter plate has been pre-coated with an antibody specific for M-CSF. Standards and samples are added to the wells, where M-CSF binds to the immobilized capture antibody. Following incubation, unbound components are removed by washing and a biotinylated detection antibody specific for M-CSF is added to the wells. The detection antibody binds the captured M-CSF to form an antibody-antigen-antibody sandwich complex. After further incubation and washing, HRP-Streptavidin conjugate is added to the wells. TMB substrate solution is then added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the yellow colour is directly proportional to the amount of M-CSF captured in each well. The concentration of M-CSF is calculated by reading the absorbance at 450 nm and comparing the values with the standard curve.