Sari la conținut
Coșul meu

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Hydroxyproline ELISA Kit

Pe scurt

Hydroxyproline ELISA Kit este un kit ELISA de tip Competitive (quantitative) pentru măsurarea Hydroxyproline, cu reactivitate declarată pentru Universal. Măsoară în domeniul 78.1-5000 ng/ml, are o sensibilitate de 33 ng/ml, folosește detecție Colourmetric și se poate folosi pe probe de tip Serum, plasma, tissue homogenates or other biological fluids. Se livrează în mărimile 48T și 96T, la prețuri între 4.625,23 și 6.122,60 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Hydroxyproline ELISA Kit is a competitive Enzyme-Linked Immunosorbent Assay (cELISA) designed for the in vitro quantitative determination of Hydroxyproline in serum, plasma, tissue homogenates or other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărimi disponibile
48T · 96T
Applications
Competitive ELISA
Reactivity
Universal
Sensitivity
33 ng/ml
Detection type
Colourmetric
Product range
78.1-5000 ng/ml
Assay Time
2h 30m
Principiul testului
Hydroxyproline ELISA Kit (A2097) employs the competitive enzyme immunoassay technique for the quantitative measurement of Hydroxyproline in serum, plasma, tissue homogenates or other biological fluids. The 96-well microtiter plate has been pre-coated with Hydroxyproline antigen. During the incubation, Hydroxyproline present in the samples or standards competes with the fixed amount of immobilized Hydroxyproline for binding sites on the Biotinylated Anti-Hydroxyproline Antibody. The more Hydroxyproline present in a sample or standard, the less Biotinylated Anti-Hydroxyproline Antibody that binds to the plate. Following incubation, unbound Biotinylated Anti-Hydroxyproline Antibody is removed by washing, and an HRP-Avidin conjugate is added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is inversely proportional to the amount of Hydroxyproline present in each sample or standard. The concentration of Hydroxyproline can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.

Documentație

Produse similare

Ai nevoie de ajutor?

Nu găsești produsul potrivit? Scrie-ne cerințele și îți răspundem cu o recomandare și un preț.

Solicită consultanță

Achiziții publice

Suntem înregistrați în SEAP și livrăm către instituții publice, cu documentație completă.

Cum cumperi prin SEAP →

Contact