Sari la conținut
Coșul meu

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Human ZDHHC9 ELISA Kit

Pe scurt

Human ZDHHC9 ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea ZDHHC9, cu reactivitate declarată pentru Human. Măsoară în domeniul 78.125-5000 pg/ml, are o sensibilitate de 46.875 pg/ml, folosește detecție Colorimetric Detection (OD450) și se poate folosi pe probe de tip Serum, plasma, tissue homogenates, and other biological fluids. Se livrează în mărimea 96T, la prețul de 4.591,95 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human ZDHHC9 ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human ZDHHC9 in serum, plasma, tissue homogenates, and other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Țintă
ZDHHC9
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
46.875 pg/ml
Product range
78.125-5000 pg/ml
Assay Time
4 hours
Principiul testului
Human ZDHHC9 ELISA Kit (A302839) is a 4 hour sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human ZDHHC9 in serum, plasma, tissue homogenates, and other biological fluids. A 96-well microtiter plate has been pre-coated with an antibody specific for ZDHHC9. Standards and samples are added to the wells, where ZDHHC9 binds to the immobilized capture antibody. Following incubation, unbound components are removed by washing and a biotinylated detection antibody specific for ZDHHC9 is added to the wells. The detection antibody binds the captured ZDHHC9 to form an antibody-antigen-antibody sandwich complex. After further incubation and washing, HRP-Streptavidin conjugate is added to the wells. TMB substrate solution is then added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the yellow colour is directly proportional to the amount of ZDHHC9 captured in each well. The concentration of ZDHHC9 is calculated by reading the absorbance at 450 nm and comparing the values with the standard curve.

Documentație

Produse similare

Ai nevoie de ajutor?

Nu găsești produsul potrivit? Scrie-ne cerințele și îți răspundem cu o recomandare și un preț.

Solicită consultanță

Achiziții publice

Suntem înregistrați în SEAP și livrăm către instituții publice, cu documentație completă.

Cum cumperi prin SEAP →

Contact