Human VCAM-1 ELISA Kit

Pe scurt

Human VCAM-1 ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea VCAM-1, cu reactivitate declarată pentru Human. Măsoară în domeniul 15.63 - 1000 pg/ml, are o sensibilitate de 3.85 pg/ml, folosește detecție Colorimetric și se poate folosi pe probe de tip Serum, plasma, cell culture supernates and other biological fluids. Se livrează în mărimea 96T, la prețul de 3.360,78 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human VCAM-1 ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human VCAM-1 in serum, plasma, cell culture supernates and other biological fluids

Citește mai multArată mai puțin

Specificații

Mărime
96T
Țintă
VCAM-1
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
3.85 pg/ml
Detection type
Colorimetric
Product range
15.63 - 1000 pg/ml
Assay Time
4 hours
Principiul testului
Human VCAM-1 ELISA Kit (A330050) employs the sandwich enzyme immunoassay technique for the quantitative measurement of human VCAM-1 in serum, plasma, cell culture supernates and other biological fluids An antibody specific for VCAM-1 has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the VCAM-1 present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-VCAM-1 Antibody, which binds the captured VCAM-1 present in each well. Following incubation, unbound biotinylated detection antibody is removed by washing, and an HRP-Streptavidin conjugate is added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of VCAM-1 captured in each well. The concentration of VCAM-1 can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.