Sari la conținut
Coșul meu

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Human TRAP/CD40L ELISA Kit

Pe scurt

Human TRAP/CD40L ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea TRAP/CD40L, cu reactivitate declarată pentru Human. Măsoară în domeniul 0.156-10 ng/ml, are o sensibilitate de 0.051 ng/ml, folosește detecție Colourmetric și se poate folosi pe probe de tip Serum, plasma, tissue homogenates, cell lysates or other biological fluids. Se livrează în mărimile 48T și 96T, la prețuri între 3.959,73 și 5.190,90 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human TRAP/CD40L ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human TRAP/CD40L in serum, plasma, tissue homogenates, cell lysates or other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărimi disponibile
48T · 96T
Țintă
TRAP/CD40L
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
0.051 ng/ml
Detection type
Colourmetric
Product range
0.156-10 ng/ml
Assay Time
4h 30m
Principiul testului
Human TRAP/CD40L ELISA Kit (A3053) employs the sandwich enzyme immunoassay technique for the quantitative measurement of human TRAP/CD40L in serum, plasma, tissue homogenates, cell lysates or other biological fluids. An antibody specific for TRAP/CD40L has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the TRAP/CD40L present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-TRAP/CD40L Antibody, which binds the captured TRAP/CD40L present in each well. HRP-Avidin conjugate is then added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of TRAP/CD40L captured in each well. The concentration of TRAP/CD40L can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.

Documentație

Produse similare

Ai nevoie de ajutor?

Nu găsești produsul potrivit? Scrie-ne cerințele și îți răspundem cu o recomandare și un preț.

Solicită consultanță

Achiziții publice

Suntem înregistrați în SEAP și livrăm către instituții publice, cu documentație completă.

Cum cumperi prin SEAP →

Contact