Human Semaphorin 3F ELISA Kit

Pe scurt

Human Semaphorin 3F ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea Semaphorin 3F, cu reactivitate declarată pentru Human. Măsoară în domeniul 46.8-3000 pg/ml, are o sensibilitate de 19.25 pg/ml, folosește detecție Colourmetric și se poate folosi pe probe de tip Serum, plasma, tissue homogenates or other biological fluids. Se livrează în mărimile 48T și 96T, la prețuri între 4.525,40 și 5.989,50 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human Semaphorin 3F ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human Semaphorin 3F in serum, plasma, tissue homogenates or other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărimi disponibile
48T · 96T
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
19.25 pg/ml
Detection type
Colourmetric
Product range
46.8-3000 pg/ml
Assay Time
4h 30m
Principiul testului
Human Semaphorin 3F ELISA Kit (A5654) employs the sandwich enzyme immunoassay technique for the quantitative measurement of human Semaphorin 3F in serum, plasma, tissue homogenates or other biological fluids. An antibody specific for Semaphorin 3F has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the Semaphorin 3F present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-Semaphorin 3F Antibody, which binds the captured Semaphorin 3F present in each well. HRP-Avidin conjugate is then added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of Semaphorin 3F captured in each well. The concentration of Semaphorin 3F can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.