Human RRAD ELISA Kit

Pe scurt

Human RRAD ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea RRAD, cu reactivitate declarată pentru Human. Măsoară în domeniul 31.25 - 2000 pg/ml, are o sensibilitate de 18.75 pg/ml, folosește detecție Colorimetric Detection (OD450) și se poate folosi pe probe de tip Serum, plasma, tissue homogenates, and other biological fluids. Se livrează în mărimea 96T, la prețul de 4.591,95 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human RRAD ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human RRAD in serum, plasma, tissue homogenates, and other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Țintă
RRAD
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
18.75 pg/ml
Product range
31.25 - 2000 pg/ml
Assay Time
4 hours
Principiul testului
Human RRAD ELISA Kit (A302920) is a 4 hour sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human RRAD in serum, plasma, tissue homogenates, and other biological fluids. A 96-well microtiter plate has been pre-coated with an antibody specific for RRAD. Standards and samples are added to the wells, where RRAD binds to the immobilized capture antibody. Following incubation, unbound components are removed by washing and a biotinylated detection antibody specific for RRAD is added to the wells. The detection antibody binds the captured RRAD to form an antibody-antigen-antibody sandwich complex. After further incubation and washing, HRP-Streptavidin conjugate is added to the wells. TMB substrate solution is then added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the yellow colour is directly proportional to the amount of RRAD captured in each well. The concentration of RRAD is calculated by reading the absorbance at 450 nm and comparing the values with the standard curve.