Human RPL13A ELISA Kit

Pe scurt

Human RPL13A ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea RPL13A, cu reactivitate declarată pentru Human. Măsoară în domeniul 0.156-10 ng/ml, are o sensibilitate de 0.058 ng/ml, folosește detecție Colourmetric și se poate folosi pe probe de tip Tissue homogenates or other biological fluids. Se livrează în mărimile 48T și 96T, la prețuri între 4.525,40 și 5.989,50 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human RPL13A ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human RPL13A in tissue homogenates or other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărimi disponibile
48T · 96T
Țintă
RPL13A
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
0.058 ng/ml
Detection type
Colourmetric
Product range
0.156-10 ng/ml
Assay Time
4h 30m
Principiul testului
Human RPL13A ELISA Kit (A7378) employs the sandwich enzyme immunoassay technique for the quantitative measurement of human RPL13A in tissue homogenates or other biological fluids. An antibody specific for RPL13A has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the RPL13A present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-RPL13A Antibody, which binds the captured RPL13A present in each well. HRP-Avidin conjugate is then added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of RPL13A captured in each well. The concentration of RPL13A can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.