Human NPR-B ELISA Kit

Pe scurt

Human NPR-B ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea NPR-B, cu reactivitate declarată pentru Human. Măsoară în domeniul 2.5-160 ng/ml, are o sensibilitate de 1.5 ng/ml, folosește detecție Colorimetric Detection (OD450) și se poate folosi pe probe de tip Serum, plasma, tissue homogenates, and other biological fluids. Se livrează în mărimea 96T, la prețul de 4.392,30 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human NPR-B ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human NPR-B in serum, plasma, tissue homogenates, and other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Țintă
NPR-B
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
1.5 ng/ml
Product range
2.5-160 ng/ml
Assay Time
4 hours
Principiul testului
Human NPR-B ELISA Kit (A78538) is a 4 hour sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human NPR-B in serum, plasma, tissue homogenates, and other biological fluids. A 96-well microtiter plate has been pre-coated with an antibody specific for NPR-B. Standards and samples are added to the wells, where NPR-B binds to the immobilized capture antibody. Following incubation, unbound components are removed by washing and a biotinylated detection antibody specific for NPR-B is added to the wells. The detection antibody binds the captured NPR-B to form an antibody-antigen-antibody sandwich complex. After further incubation and washing, HRP-Streptavidin conjugate is added to the wells. TMB substrate solution is then added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the yellow colour is directly proportional to the amount of NPR-B captured in each well. The concentration of NPR-B is calculated by reading the absorbance at 450 nm and comparing the values with the standard curve.