Human NPEPPS ELISA Kit

Pe scurt

Human NPEPPS ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea NPEPPS, cu reactivitate declarată pentru Human. Măsoară în domeniul 0.312-20 ng/ml, are o sensibilitate de 0.118 ng/ml, folosește detecție Colourmetric și se poate folosi pe probe de tip Tissue homogenates, cell lysates or other biological fluids. Se livrează în mărimile 48T și 96T, la prețuri între 4.259,20 și 5.523,65 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human NPEPPS ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human NPEPPS in tissue homogenates, cell lysates or other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărimi disponibile
48T · 96T
Țintă
NPEPPS
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
0.118 ng/ml
Detection type
Colourmetric
Product range
0.312-20 ng/ml
Assay Time
4h 30m
Principiul testului
Human NPEPPS ELISA Kit (A7516) employs the sandwich enzyme immunoassay technique for the quantitative measurement of human NPEPPS in tissue homogenates, cell lysates or other biological fluids. An antibody specific for NPEPPS has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the NPEPPS present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-NPEPPS Antibody, which binds the captured NPEPPS present in each well. HRP-Avidin conjugate is then added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of NPEPPS captured in each well. The concentration of NPEPPS can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.