Human MPP2/DLG2 ELISA Kit

Pe scurt

Human MPP2/DLG2 ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea MPP2/DLG2, cu reactivitate declarată pentru Human. Măsoară în domeniul 0.625-40 ng/ml, are o sensibilitate de 0.16 ng/ml și folosește detecție Colourmetric. Se livrează în mărimile 48T și 96T, la prețuri între 3.959,73 și 5.190,90 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human MPP2/DLG2 ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human MPP2/DLG2 in serum, plasma, tissue homogenates, cell lysates, cell culture supernates or other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărimi disponibile
48T · 96T
Țintă
MPP2/DLG2
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
0.16 ng/ml
Detection type
Colourmetric
Product range
0.625-40 ng/ml
Assay Time
4h 30m
Principiul testului
Human MPP2/DLG2 ELISA Kit (A2844) employs the sandwich enzyme immunoassay technique for the quantitative measurement of human MPP2/DLG2 in serum, plasma, tissue homogenates, cell lysates, cell culture supernates or other biological fluids. An antibody specific for MPP2/DLG2 has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the MPP2/DLG2 present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-MPP2/DLG2 Antibody, which binds the captured MPP2/DLG2 present in each well. HRP-Avidin conjugate is then added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of MPP2/DLG2 captured in each well. The concentration of MPP2/DLG2 can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.