Human MMP13 ELISA Kit

Pe scurt

Human MMP13 ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea MMP13, cu reactivitate declarată pentru Human. Măsoară în domeniul 0.156-10 ng/ml, are o sensibilitate de 0.062 ng/ml și folosește detecție Colourmetric. Se livrează în mărimile 48T și 96T, la prețuri între 3.959,73 și 5.190,90 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human MMP13 ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human MMP13 in serum, plasma, tissue homogenates, cell lysates, cell culture supernates or other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărimi disponibile
48T · 96T
Țintă
MMP13
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
0.062 ng/ml
Detection type
Colourmetric
Product range
0.156-10 ng/ml
Assay Time
4h 30m
Principiul testului
Human MMP13 ELISA Kit (A2815) employs the sandwich enzyme immunoassay technique for the quantitative measurement of human MMP13 in serum, plasma, tissue homogenates, cell lysates, cell culture supernates or other biological fluids. An antibody specific for MMP13 has been pre-coated onto a 96-well microtiter plate. The standards and test samples are added into the wells and the MMP13 present in each sample is bound to the wells by the immobilized antibody. Following incubation, the wells are washed and then incubated with Biotinylated Anti-MMP13 Antibody, which binds the captured MMP13 present in each well. HRP-Avidin conjugate is then added to the wells and the microtiter plate is incubated. Following incubation and washing, TMB substrate solution is then used to visualize the HRP enzymatic reaction by catalysis to produce a blue-coloured product that changes to yellow after addition of acidic stop solution. The density of yellow is proportional to the amount of MMP13 captured in each well. The concentration of MMP13 can then be calculated by reading the O.D. absorbance at 450nm in a microplate reader and referring to the standard curve.