Sari la conținut
Coșul meu

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Human Lrp2/Megalin ELISA Kit

Pe scurt

Human Lrp2/Megalin ELISA Kit este un kit ELISA de tip Sandwich (quantitative) pentru măsurarea LRP2/Megalin, cu reactivitate declarată pentru Human. Măsoară în domeniul 0.781-50 ng/ml, are o sensibilitate de 0.469 ng/ml, folosește detecție Colorimetric Detection (OD450) și se poate folosi pe probe de tip Serum, plasma, tissue homogenates, and other biological fluids. Se livrează în mărimea 96T, la prețul de 4.392,30 lei cu TVA.

Produse destinate exclusiv cercetării. Nu se utilizează în diagnostic sau tratament.

Descriere

Human Lrp2/Megalin ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human Lrp2/Megalin in serum, plasma, tissue homogenates, and other biological fluids.

Citește mai multArată mai puțin

Specificații

Mărime
96T
Applications
Sandwich ELISA
Reactivity
Human
Sensitivity
0.469 ng/ml
Product range
0.781-50 ng/ml
Assay Time
4 hours
Principiul testului
Human Lrp2/Megalin ELISA Kit (A78398) is a 4 hour sandwich Enzyme-Linked Immunosorbent Assay (sELISA) designed for the in vitro quantitative determination of human Lrp2/Megalin in serum, plasma, tissue homogenates, and other biological fluids. A 96-well microtiter plate has been pre-coated with an antibody specific for Lrp2/Megalin. Standards and samples are added to the wells, where Lrp2/Megalin binds to the immobilized capture antibody. Following incubation, unbound components are removed by washing and a biotinylated detection antibody specific for Lrp2/Megalin is added to the wells. The detection antibody binds the captured Lrp2/Megalin to form an antibody-antigen-antibody sandwich complex. After further incubation and washing, HRP-Streptavidin conjugate is added to the wells. TMB substrate solution is then added to visualize the HRP enzymatic reaction. This produces a blue-coloured product that changes to yellow following addition of acidic stop solution. The intensity of the yellow colour is directly proportional to the amount of Lrp2/Megalin captured in each well. The concentration of Lrp2/Megalin is calculated by reading the absorbance at 450 nm and comparing the values with the standard curve.

Documentație

Produse similare

Ai nevoie de ajutor?

Nu găsești produsul potrivit? Scrie-ne cerințele și îți răspundem cu o recomandare și un preț.

Solicită consultanță

Achiziții publice

Suntem înregistrați în SEAP și livrăm către instituții publice, cu documentație completă.

Cum cumperi prin SEAP →

Contact